Skip to content

Nexsan E60 Tech Specs

Technical Specifications
Item Specification
Disk Bays 60
Rack U 4U
Controllers Standard
Dual Optional Active/Active fault-tolerance and increased performance with optional second controller
Supports E60X Expansion No
Battery Protected Cache per Controller 4GB
Host Ports 2 FC 8Gbit ports & 2 iSCSI 1Gbit ports per controller
Storage Expansion Ports for E60X N/A
Hardware RAID 6 Included
RAID Levels 0, 1, 1+0, 4, 5, 6
Volumes and LUNs 254 volumes per system / 254 LUNs per port
Standard Dual Redundant Power Supplies Two 1600 watt – 220-240v power supplies
Dimensions Fits into a 1200mm 19 inch rack Width is 19 inches / 48.26 cm. Height is 7 inches / 17.78 cm. (4U) Depth is 40.36 inches / 102.6 cm.
Maximum Installed Weight w/ mounting rails, all drives and controllers approx - 102 Kg / 225 lbs
Operating Temperature Range 5ºC to 35ºC (41ºF to 95ºF)
Operating Humidity Range 20% to 80% non-condensing
Operating Altitude 0 to 2,133m (0 to 7,000ft)
Non-operational Altitude 0 to 12,192m (0 to 40,000ft)