Skip to content

Nexsan E60 Features

Features Benefits
Up to 60 Disks Unsurpassed storage density and capacity in 4U.
Mix SAS, SATA, and SSD drives Optimize storage for cost, capacity, and performance to meet the needs of varying applications.
Active Drawer Technology Allows one person to easily gain access to hot-swappable disks and fans, in any of the three sliding drawers, which remain operational when opened.
High Availability Can be configured so there is no single point of failure between the servers and storage system, or within the storage system. All power, fans, disks, and I/O ports are fully redundant.
Active / Active When both controllers are health, they each service storage requests, delivering twice the performance of the active/passive architecture offered by others.
Energy Savings AutoMAID is the industry’s most sophisticated power management system. Drives which contain backups or occasionally accessed data can be powered down when not being used, saving up to 87% on electricity and cooling costs.
Anti-vibration Design Hard drives are mounted so that all disks are not spinning in the same direction. This, plus the advanced anti-vibration chassis combine to provide unprecedented hard drive MTBFs.
Cool Drive Technology The chassis is designed to deliver uniform, plentiful airflow that is not subject to a single point of failure. The hot-swappable fan on the front of a drawer pulls in air, and two fans at the rear push the air out.
Fibre Channel and iSCSI SAN Connectivity Each controller provides two 8Gb/sec Fibre Channel ports, and two 1Gb/s iSCSI connections – all four ports can be used simultaneously in SAN or direct-attached applications.
Revolutionary Ease of Administration A built-in Web server utilizes the dedicated 100Mb/s Ethernet port to deliver an industry-leading GUI that sets the gold standard for ease of management.
4GB Battery-backed Cache per Controller The two RISC engines on each controller share a 4GB high speed cache which is supplied with enough battery power to permit it to be saved to flash memory in the event of a sudden loss of power.
Hardware RAID Supports RAID 0, 1, 1+0, 4, 5, and 6 using two dedicated hardware RAID engines per controller. RAID6 protects against the failure of two drives in a RAID set.
Automatic RAID Set Maintenance In the event of a drive failure, spare drives are automatically added to a RAID set and a RAID set rebuild is run – all without any manual intervention being required. Administrator can receive email alerts, SNMP alerts, or monitor the storage system’s health remotely.
Flexible Storage Configuration Supports multiple RAID sets and multiple volumes per set with full LUN security and up to 254 LUNS per system.
Redundant Power Dual redundant 220-240V power supplies
Rack A 1200 mm rack is required to accommodate the depth of the storage system. Cable contol is internal to the storage system’s 3 active drawers.